Knowledge Why is data from the first two steps discarded in gait analysis? Ensure Accurate Smart Footwear Bio-Metrics
Author avatar

Tech Team · 3515

Updated 3 days ago

Why is data from the first two steps discarded in gait analysis? Ensure Accurate Smart Footwear Bio-Metrics


Data integrity depends on isolating the signal from the noise. In smart footwear gait analysis, data from the first two steps is consistently discarded because it captures the initiation phase, a transitional period where the body accelerates from a standstill. This phase lacks the rhythmic stability and consistent Center of Pressure (CoP) distribution found in continuous walking, making it statistically unrepresentative of a subject's true, natural gait.

Walking initiation is a distinct, non-steady mechanical process that introduces transient noise into datasets. Discarding these initial steps allows analysts to isolate stable gait cycles, ensuring that extracted features reflect the subject's baseline mechanics rather than their acceleration strategy.

The Mechanics of Walking Initiation

The Transition from Static to Dynamic

The first two steps constitute a non-steady-state process. Moving from a static posture to a dynamic walk requires a unique application of force to break inertia.

Because the body is actively accelerating, the biomechanics of these steps differ fundamentally from the pendulum-like conservation of energy seen in steady walking.

Instability in Center of Pressure (CoP)

During initiation, the Center of Pressure distribution has not yet stabilized. The foot-to-ground interaction is focused on generating forward momentum rather than maintaining balance.

Including this data would skew the analysis of weight distribution, potentially creating false positives for balance irregularities that are actually just normal acceleration mechanics.

Establishing Gait Rhythm

A natural walking state is defined by a consistent periodicity, or gait rhythm. It takes approximately two steps for the neurological and mechanical systems to settle into this rhythmic pattern.

Data collected before this synchronization occurs is irregular. It does not reflect the subconscious, repetitive motion that gait analysis aims to measure.

Ensuring Data Fidelity

Filtering Transient Noise

The initiation phase introduces transient noise—irregular data spikes caused by the effort of starting movement.

By filtering out the first two steps, the system removes these irregularities. This improves the signal-to-noise ratio, making the remaining data cleaner and easier to interpret.

Capturing the Representative State

The ultimate goal of most gait experiments is to characterize the subject's representative natural walking state.

If the initiation phase is included, the resulting averages will be a hybrid of "starting" and "walking." Discarding the start ensures the features extracted are purely indicative of how the subject walks over distance.

Understanding the Trade-offs

Loss of Acceleration Data

The primary trade-off of this filtering technique is the total loss of initiation metrics.

If the specific goal of a study is to analyze how a subject generates starting torque or overcomes inertia, this standard filtration method would destroy the relevant data.

Assumption of Stability

This method assumes that the subject does stabilize after two steps.

While true for healthy subjects, in populations with severe motor control issues, a "steady state" might never be reached. In such edge cases, discarding the first two steps might simply exchange one type of unstable data for another.

Making the Right Choice for Your Goal

To ensure your gait analysis yields actionable insights, apply this filtration logic based on your specific objectives:

  • If your primary focus is Baseline Profiling: Discard the first two steps to ensure your metrics reflect the subject's subconscious, rhythmic walking habit.
  • If your primary focus is Feature Accuracy: Remove the initiation phase to prevent acceleration artifacts from skewing your Center of Pressure and rhythm averages.

By strictly isolating steady-state cycles, you convert raw sensor data into a reliable clinical or biometric benchmark.

Summary Table:

Factor Initiation Phase (First 2 Steps) Steady-State Phase (Continuous Walking)
Mechanical State Non-steady (acceleration to break inertia) Stable (pendulum-like energy conservation)
CoP Stability High variability (focus on momentum) Stabilized (focus on balance)
Gait Rhythm Irregular/Developing Consistent periodicity
Data Impact Transient noise & acceleration artifacts Representative baseline mechanics

Partner with 3515 for Precision-Engineered Footwear Solutions

As a large-scale manufacturer serving global distributors and brand owners, 3515 offers comprehensive production capabilities across all footwear categories. Whether you are developing advanced Safety Shoes, tactical boots, or high-performance sneakers, our flagship manufacturing processes ensure the structural integrity required for precise gait analysis and long-term durability.