Knowledge Resources What function does an automatic mechanical shaker perform in the hexavalent chromium extraction process? Ensure ISO Compliance and Accurate Results
Author avatar

Tech Team · 3515

Updated 1 week ago

What function does an automatic mechanical shaker perform in the hexavalent chromium extraction process? Ensure ISO Compliance and Accurate Results


The automatic mechanical shaker serves as the critical driver of consistency in the hexavalent chromium extraction process. It provides constant-speed agitation to the mixture of leather powder and reagents, typically over a specific duration such as three hours. This continuous, automated motion removes the variability of manual handling and ensures the extraction environment remains stable.

By eliminating local concentration gradients and enhancing convective mass transfer, the shaker ensures that hexavalent chromium ions reach chemical equilibrium. This is the fundamental requirement for achieving high-recovery extraction that complies with ISO 17075 standards.

The Mechanism of Extraction

Constant-Speed Agitation

The primary function of the shaker is to maintain a specific, constant speed of agitation. Unlike manual mixing, which fluctuates, the automatic shaker ensures that every sample is treated with the exact same physical force.

Enhancing Convective Mass Transfer

Static interactions between solids and liquids are often slow and inefficient. The mechanical vibration generates convective mass transfer, actively moving ions from the solid leather matrix into the liquid solution.

Optimizing the Liquid-Solid Interface

The extraction process relies on the interaction between the leather powder and the reagents. The shaker maximizes contact at this liquid-solid interface, ensuring no particle is left unexposed to the extraction medium.

Achieving Chemical Equilibrium

Eliminating Concentration Gradients

Without adequate mixing, pockets of high concentration can form immediately around the solid particles, slowing down the extraction. The shaker prevents this by eliminating local concentration gradients across the entire vessel.

High-Recovery Extraction

The goal of the process is to recover the maximum amount of hexavalent chromium possible for analysis. By maintaining agitation until chemical equilibrium is reached, the shaker ensures the data reflects the true content of the sample.

Adhering to Time Parameters

The process often requires a sustained duration, such as 3 hours, to be effective. The automatic nature of the shaker allows this precise timing to be met without interruption or fatigue.

Operational Constraints and Considerations

Dependency on ISO 17075 Standards

The use of an automatic mechanical shaker is not merely a preference; it is often dictated by ISO 17075 standards. Deviating from the specified mechanical agitation can render the resulting data non-compliant and invalid for certified testing.

The Risk of Manual Methods

Attempting to replicate this process manually introduces significant error. Human agitation cannot replicate the consistent mechanical vibration required to guarantee that equilibrium is reached uniformly across all samples.

Making the Right Choice for Your Goal

To ensure your extraction process yields valid, professional-grade results, align your equipment use with your specific objectives:

  • If your primary focus is Regulatory Compliance: Ensure your equipment settings explicitly match the constant-speed and time duration requirements of ISO 17075.
  • If your primary focus is Data Accuracy: Prioritize the elimination of concentration gradients by verifying the shaker maintains vigorous, uninterrupted convective mass transfer throughout the full cycle.

Reliable extraction is not just about mixing chemicals; it is about creating the precise physical conditions required for chemical equilibrium.

Summary Table:

Feature Function/Benefit Impact
Constant Agitation Maintains precise, unwavering speed & duration Eliminates manual variability, ensures stable environment
Convective Mass Transfer Actively moves ions from solid leather to liquid solution Optimizes extraction efficiency, maximizes interface
Chemical Equilibrium Eliminates local concentration gradients, ensures full reaction Achieves high-recovery extraction, guarantees data accuracy
ISO 17075 Compliance Adheres to mandated mechanical agitation specifications Ensures data validity for certified testing

As a large-scale manufacturer serving distributors and brand owners, 3515 offers comprehensive production capabilities for all footwear types, anchored by our flagship Safety Shoes series. Our extensive portfolio covers work and tactical boots, outdoor shoes, training shoes, and sneakers, as well as Dress & Formal shoes to meet diverse bulk requirements. We ensure precision and compliance in every step of our manufacturing. To discuss your specific footwear production needs and leverage our expertise in quality and regulatory adherence, contact our team today! Contact Us Now

References

  1. Kallen Mulilo Nalyanya, Paul Kamau. Mitigating the Formation of Hexavalent Chromium in Leather by Using Aloe Barbadensis Miller Mixed with Carrageenan. DOI: 10.31881/tlr.2021.20

This article is also based on technical information from 3515 Knowledge Base .